HVACDatabase
HVAC Contractor Directory

Heat Pump vs Current System: 10-Year Cost Comparison

Compare two heating scenarios using your energy consumption, tariffs, quoted installation costs, and confirmed incentives. All assumptions and formulas are shown.

Use heating-only energy consumption and prices from your bills. Convert therms, cubic metres, litres, or MJ to kWh using your supplier's stated conversion before entering them. This comparison excludes cooling and hot water. All monetary inputs use USD.

Efficiency 0.9 and COP 3 are illustrative starting assumptions, not measurements of your home. Ask the installer for a seasonal performance estimate including backup heat.

Calculation and limitations

Delivered heat = heating fuel kWh ? existing efficiency. Heat-pump electricity = delivered heat ? assumed seasonal COP. Each operating cost is energy ? its unit price. The ten-year comparison uses constant prices and subtracts the difference in installation costs after the confirmed incentive.

It excludes financing, discounting, maintenance, equipment lifespan, fixed utility charges, cooling, and changes in comfort or usage. The assumed seasonal COP must account for local conditions and backup heating; a single laboratory COP may not represent a whole winter. No rebate is assumed automatically.

Reference: Natural Resources Canada: heat-pump efficiency and seasonal performance. Formula and assumptions reviewed November 10, 2026.